Electrical Tests

Electrical Tests

¡ö Electrical Test Items

Contact Resistance, Insulation Resistance, Electrical Strength, Temperature Rise, Breaking Capacity, Over Load Test.
Steady standard inspection is in accordance of IEC-60320, EN 60320, UL 498, CSA C22 & GB 17465


¡ö Electrical Test Equipments

Hipot Tester

Hipot Tester can inspect insulation resistance to resist moisture between housing & terminal. In addition,it can test electrical strength between all terminals to meet safety.

  • FUNCTION£ºInsulation Resistance Electrical Strength
  • OUTPUT£ºAC:0~5KV
  • INSULATION RESISTANCE£º1M¦¸~5G¦¸

Resistance Meter

To ensure contact conduction between terminals,Resistance Meter can test contact resistance between input and output of sockets.

  • FUNCTION£ºContact resistance
  • RANGE£º0.01m¦¸~199.99K¦¸
  • ACCURACY£º¡À0.1%

AC Source & Load Equipment

AC Source & Load Equipment can inspect mechanic ,electric,and thermal stress from sockets in normal usage condition.
In addition, it can test breaking capacity of sockets by rising electrical pressure to simulate withdraw force.

  • FUNCTION£ºTemperature Rise Breaking Capacity
  • RANGE£º300V/20A(AC)